Datasheet is currently unavailable. Try again or  CONTACT US
                    
                
            Fluorescein (FITC) Antibody
Goat Polyclonal
                
                8 References
            
        
            
                600-101-096S
                600-101-096
        
        
            
                25 µL
                1 mg
        
            
                
                    Liquid (sterile filtered)
                    Liquid (sterile filtered)
            
            
                
                WB, ELISA, FISH, Microarray
            
                    
                
                Fluorescein
            
                            
                
                 Goat
            
                
            
        
        Shipping info:
        
    Find your nearest distributor for timely delivery and local support.
Product Details
                    
                    
Anti-Fluorescein (GOAT) Antibody - 600-101-096                    
                
                
                    
                    
goat Anti FITC, goat anti Fluorescein                    
                
                
                    
                    
Goat                    
                
                
                    
                    
Polyclonal                    
                
                
                    
                    
IgG                    
                
            Target Details
                    
                    
Fluorescein                                            
                
                
                    
                    
Other                                            
                
                
                    
                    
Fluorescein conjugated to Goat IgG                                            
                
                
                    
                    
Fluorescein Antibody was prepared from monospecific antiserum by immunoaffinity chromatography using Fluorescein conjugated Goat IgG coupled to agarose beads followed by solid phase adsorption(s) to remove any unwanted reactivities.   Assay by immunoelectrophoresis resulted in a single precipitin arc against anti-Goat Serum and Fluorescein conjugated Bovine Serum Albumin.                                            
                
                Application Details
                        
                        
ELISA, WB
                        
                    
                    
                        
                        
FISH, Microarray
 - View References 
                        
                    
                    
                        
                        
Anti-Fluorescein Antibody has been tested by ELISA and western blot and is suitable for immunomicroscopy, in situ hybridization and flow cytometry or FACS analysis as well as other antibody based fluorescent assays requiring lot-to-lot consistency.
                        
                    
                                                    Formulation
                        
                        
1.2mg/mL by UV absorbance at 280 nm                        
                    
                    
                        
                        
0.02 M Potassium Phosphate, 0.15 M Sodium Chloride, pH 7.2                        
                    
                    
                        
                        
0.01% (w/v) Sodium Azide                        
                    
                    
                        
                        
None                        
                    
            Shipping & Handling
                    
                    
Wet Ice                    
                
                
                    
                    
Store vial at 4° C prior to opening.  Aliquot contents and freeze at -20° C or below for extended storage.  Avoid cycles of freezing and thawing.  Centrifuge product if not completely clear after standing at room temperature.  This product is stable for several weeks at 4° C as an undiluted liquid.  Dilute only prior to immediate use.                      
                
                
                    
                    
Expiration date is one (1) year from date of receipt.                    
                
        
                Anti-Fluorescein Antibody is designed for immunofluorescence microscopy, fluorescence based plate assays (FLISA) and fluorescent western blotting.  Anti-FITC is also suitable as a visualization reagent for fluorescein-labelled compounds (such as antibodies, lectins and peptide nucleic acid (PNA) probes).
            
        
                            John S Cognetti et al. (2021). Disposable photonics for cost-effective clinical bioassays: application to COVID-19 antibody testing. Lab Chip.
                        
                        Applications
                            Microfluidic Point of Care Chip Immunoassay
                        
                            Asafen HA et al. (2020). Robustness of the Dorsal morphogen gradient with respect to morphogen dosage. PLoS Comput Biol.
                        
                        Applications
                            ISH, FISH
                        
                            Jacobsen T et al. (2020). Tunable self-cleaving ribozymes for modulating gene expression in eukaryotic systems. PLoS One
                        
                        Applications
                            ISH, FISH
                        
                            Liu et al. (2017). Bach1 siRNA attenuates bleomycin-induced pulmonary fibrosis by modulating oxidative stress in mice. International Journal of Molecular Medicine
                        
                        Applications
                            WB, IB, PCA
                        
                            Fu et al. (2017). Activation of cannabinoid receptor type 2 by JWH133 alleviates bleomycin-induced pulmonary fibrosis in mice. Oncotarget
                        
                        Applications
                            WB, IB, PCA
                        
                            Guest et al. (2015). Survival of irradiated recipient mice after transplantation of bone marrow from young, old and "early aging" mice. Aging
                        
                        Applications
                            ISH, FISH
                        
                            Bucukovski, J et al. (2015). A Multiplex Label-Free Approach to Avian Influenza Surveillance and Serology. PloS One
                        
                        Applications
                            Microarray, Microarray chip
                        
                            Guest I et al. (2010). Direct and indirect contribution of bone marrow‐derived cells to cancer. Int J Cancer.
                        
                        Applications
                            ISH, FISH
                        
            This product is for research use only and is not intended for therapeutic or diagnostic applications.  Please contact a technical service representative for more information.  All products of animal origin manufactured by Rockland Immunochemicals are derived from starting materials of North American origin.  Collection was performed in United States Department of Agriculture (USDA) inspected facilities and all materials have been inspected and certified to be free of disease and suitable for exportation.  All properties listed are typical characteristics and are not specifications.  All suggestions and data are offered in good faith but without guarantee as conditions and methods of use of our products are beyond our control.  All claims must be made within 30 days following the date of delivery. The prospective user must determine the suitability of our materials before adopting them on a commercial scale.  Suggested uses of our products are not recommendations to use our products in violation of any patent or as a license under any patent of Rockland Immunochemicals, Inc.  If you require a commercial license to use this material and do not have one, then return this material, unopened to:  Rockland Inc., P.O. BOX 5199, Limerick, Pennsylvania, USA.
        
     
                         
                                             
                                             
                                             
                                             
                                            